(9) Lens Selection Switch (VIDEO/DC)
This switch is used to select the supplied auto iris
control signal to the lens from the Auto Iris Lens
Connector(l).
DC: Choose this position when the auto iris control
lens requiring DC control signal such as lens
es shown on pages 10,11, 12 and 13.
VIDEO: Choose this position when the auto iris
control lens requiring video signal such as
WV-U\8B, WV-LA16B, WV-LA25B, WV-LA50B,
is mounted on the camera.
(10) Gen-lock Termination Switch (G/L 75Q / Hiz)
When looping through the Gen-lock video input
signal, set this switch to the Hi-Z position and in all
other cases, set this switch to the 75-ohm position.
(11) Vertical Phase Control (V.PHASE)
The vertical phase of the camera sigani can be
adjusted to match the vertical phase of the line
power,
(12) Auto Iris Level Control (ALC LEVEL, L(Low)/
H(High))
This control adjusts the control level of the auto iris
control when the Lens Selection Switch (9) is set to
the DC position and the auto iris lens which
requires the DC control voltage such as WV-LA12
etc., is mounted on the camera.
Note: When the Lens Selection Switch (9) is set to
the VIDEO position, the auto iris control level
should be adjusted by the lens.
(13) Video Output Connector (VIDEO OUT)
A 1.0 Vp-p/75 ohms composite video signal is pro
vided at this connector.
Whenever the multiplexed vertical drive (VD2) sig
nal is supplied to this connector, the camera syn
chronization mode is automatically set to Vertical
Drive Lock.
(14) Gen-lock Video Input Connector (GEN-LOCK)
A composite B/\N or color 1.0 Vp-p/75 ohms video
signal, or black burst 0.3 Vp-p/75 ohms or com
posite sync 4 Vp-p/75 ohms should be supplied to
this connector for external synchronization.
(15) AC 24V In Terminal (AC 24V IN)
This terminal accepts 24V AC power source
(19.5V-28V), Be sure to connect grounding lead to
the GND terminal.
Cautions :
1, Connect this to a 24V AC class 2 power sup
ply only.
2. To prevent fire or shock hazard, the UL listed
wire VW-1, style 1007 should be used for the
cable for AC 24V Input Terminal.
-6-