(9) Lens Selection Switch (VIDEO/DC)

This switch is used to select the supplied auto iris

control signal to the lens from the Auto Iris Lens
Connector(l).

DC: Choose this position when the auto iris control

lens requiring DC control signal such as lens­
es shown on pages 10,11, 12 and 13.

VIDEO: Choose this position when the auto iris

control lens requiring video signal such as

WV-U\8B, WV-LA16B, WV-LA25B, WV-LA50B,

is mounted on the camera.

(10) Gen-lock Termination Switch (G/L 75Q / Hiz)

When looping through the Gen-lock video input

signal, set this switch to the Hi-Z position and in all
other cases, set this switch to the 75-ohm position.

(11) Vertical Phase Control (V.PHASE)

The vertical phase of the camera sigani can be

adjusted to match the vertical phase of the line
power,

(12) Auto Iris Level Control (ALC LEVEL, L(Low)/

H(High))

This control adjusts the control level of the auto iris

control when the Lens Selection Switch (9) is set to

the DC position and the auto iris lens which

requires the DC control voltage such as WV-LA12

etc., is mounted on the camera.

Note: When the Lens Selection Switch (9) is set to

the VIDEO position, the auto iris control level
should be adjusted by the lens.

(13) Video Output Connector (VIDEO OUT)

A 1.0 Vp-p/75 ohms composite video signal is pro­
vided at this connector.
Whenever the multiplexed vertical drive (VD2) sig­

nal is supplied to this connector, the camera syn­

chronization mode is automatically set to Vertical

Drive Lock.

(14) Gen-lock Video Input Connector (GEN-LOCK)

A composite B/\N or color 1.0 Vp-p/75 ohms video

signal, or black burst 0.3 Vp-p/75 ohms or com­
posite sync 4 Vp-p/75 ohms should be supplied to

this connector for external synchronization.

(15) AC 24V In Terminal (AC 24V IN)

This terminal accepts 24V AC power source

(19.5V-28V), Be sure to connect grounding lead to

the GND terminal.
Cautions :

1, Connect this to a 24V AC class 2 power sup­

ply only.

2. To prevent fire or shock hazard, the UL listed

wire VW-1, style 1007 should be used for the
cable for AC 24V Input Terminal.

-6-