beautypg.com

Symptom check action, Im [hi, 1 ihi 1 lj – Panasonic PanaSync S110 User Manual

Page 24

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

If trouble occurs with the display unit, perform the following checks and take the
indicated action; if the trouble persists, please consult with your dealer.

Symptom

Check

Action

Thera is no display

power cord/plug
power switch

signal cable
The power saving function might

have acted (if so the pilot LED

will be yellow).

Plug the power cord into the outlet correctly.
Press the power switch.

Connect the signal cable correctly.

Release the power saving function by operating

the mouse or keyboard.

For additional details please read the Operation
Manual of the hardware you are using.

on

The image is too large or too

small, or it is displaced from
the correct position.

The mode is not registered.

Perform the desired settings and then save them
by waiting 20 seconds or pressing the Q] “Exif key.

□ □

The display color is abnormal.

(Example) The color is
uneven or off-color.

The image distortion and or
tilt is large.

Is there something that produces

a magnetic field nearby?

(Examples) Television monitor,

another computer display unit,

speaker, etc.; was the
orientation of the monitor
perhaps changed while it was in

use?

Remove the source of the magnetic field.
Perform degaussing.
Make sure your cable is correct.

Connect the signal connector correctly.
Try a different orientation.

im [HI

The background of the image

is bright.
The background of the image

is colored.

The character gets partially
distorted.
The image is dark.

The computer in use is Macintosh.
The signal output of the computer

in use is improper.

Press the operating keys Q] and [3 together at

the same time. You can then adjust this unit with
the signal output of the computer. One more

pressing or execution of recall can cancel this
function.

*This function is effective for a specified

computer. If there is no problem in normal use,
avoid the use of this function.

1 iHi 1 LJ

Characters cannot be seen
clearly; the image is too dark.

Is the image signal level correctly

adjusted?

Is the brightness or contrast

adjustment turned all the way
down?

Check the video signal level from the computer
and adjust it in the correct direction.
Adjust the brightness and contrast.

The screen size and position
do not change.

Is the input synchronization signal
within the operating range?

Check the video output mode from the computer,
and select a mode within the display unit operating

range.

For details, please read the Operation Manual of

the hardware you are using.

The front panel keys fail to
operate.

Are 2 or more Keys being

operated at the same time?

Operate only one key at a time.

- 1 8

-