FRONT PANELS

LED version front panel

LCD version front panel


FUNCTION KEYS

PEAK – Toggles the indicator between normal live display mode and peak hold mode (Setup

5 must be set at “0” on the LCD version).

A


ZERO - Sets the FI-80 to display “0” provided the following conditions are met:
1. The FI-80 is displaying Gross load.
2. The displayed load is within the zero reset range (F4 in setup).
3. The load is not in motion (F5 in setup).
4

. The FI-80 is not in overload (see Appendix D for error codes).

NET/GROSS - Toggles the indicator between Gross load and Net load only if a Tare has

een established.

b


TARE - Establishes a Tare provided the following conditions are met:
1. The reading is not at or below Gross zero.
2. The load is not in motion.