Table 1. switch 1 and 2 utp speed settings -2, Table 2. switch 3 through 8 functions -2, Tables 1 and 2. for m – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual
Page 12
EdgeAccess Universal Chassis System
Table 1. Switch 1 and 2 UTP Speed Settings
Switch 1 Switch 2
Speed
Off Off 1000
Mbps
Off On 100
Mbps
On Off 10
Mbps
On On Autonegotiate
Table 2. Switch 3 Through 8 Functions
Switch Function
On
Off
3
Full Duplex on UTP User Port Select full duplex
Select half duplex
4
SBMC
Enable SBMC
Disable SBMC
5
LLF, Extension to User
Enable Link Loss Forwarding
(LLF) propagating from
Extension Port to User Port
Disable LLF propagating
from Extension Port to User
Port
6
LLF, User to Extension
Enable LLF propagating from
User Port to Extension Port
Disable LLF propagating
from User Port to Extension
Port
7, 8
Not used
4. To install the L357 in a BAM in a UCS 1000 or 1001, follow these steps:
a. Insert a BAM into an available slot. Slide the BAM into the rails and push it firmly into the
connector, then tighten the captive screws. If you encounter resistance, pull the BAM out and
check that no connector pins are bent.
b. Insert the L357 into an unused slot in the BAM. Slide the L357 into the rails and push it
firmly into the connector, then tighten the captive screw. If you encounter resistance, pull it
out and check that no connector pins are bent. If you encounter more difficulty, contact
Canoga Perkins at (818) 718-6300 for technical assistance.
5. To install the L357 in a UCS Model 1002 or Standalone Enclosure, insert the L357 into an
unused slot. Slide the L357 into the rails and push it firmly into the backplane, then tighten the
captive screw. If you encounter resistance, pull it out and check that no connector pins are bent.
If you encounter more difficulty, contact Canoga Perkins at (818) 718-6300 for technical
assistance.
Note: The L357 is hot-swappable and can be inserted or removed without disrupting data transfer
in other modules in the chassis.
L357 Gigabit Ethernet Service Unit