CANOGA PERKINS 3240S SNMP-Managed T1/E1 Fiber-Optic Multiplexer User Manual
Page 38

EdgeAccess
4-6 3240S Fiber-Optic Multiplexer
To run I/O port loopback in software, follow these steps:
1. From the Main Menu, type
2
, "Multiplexer Configuration/Status," and press
2. At the Multiplexer Configuration/Status screen, type
2
, "I/O port Module & Logical Address,"
and press
3. At the Unit and Slot Configuration screen, type 3, "Set/Clear Port Loopback," and then at the
prompt, enter the unit and port number.
4. To start (activate) Local or Remote Loopback for the selected port, type
2
or
3
and press
loopback starts.
5. To stop Loopback, type
1
and press
6. To return to the Main Menu, press
To run composite loopback manually, follow these steps:
1. At the rear panel, set the System Mode switch to LOC for local loopback or to REM for remote
loopback; loopback starts automatically.
2. To stop Loopback, set the System Mode switch to NORM.
To run composite loopback in software, follow these steps:
1. From the Main Menu, type
2
, "Multiplexer Configuration/Status," and press
2. At the Multiplexer Configuration/Status screen, type
1
, "System Configuration/Status," and press
3. At the System Configuration/Status screen, type 1, "Set/Clear Composite Loopback," press
4. To stop Loopback, type
1
and press
5. To return to the Main Menu, press