Table 4. Trap Configuration Options
Trap
When enabled, sends a Trap if. . .
Cold Start
The 9160 is reset by a power failure or forced reset
Remote Fault Received A port receives an RMTF
Monitor System
RMON, internal temperature, or a power supply is out of range or the fan failed
Monitor Port Module
A port module is inserted or removed
VLAN Settings
A user tries to delete the default or all VLANs
Link Up/Down
The link went down and came back up
Authentication An
unauthorized host attempts SNMP access
Spanning Tree
An STP change occurs
View System Events and Traps
The System Log lists all events that have occurred since the log was last cleared. The Traps Log lists
the traps that have occurred since the last power-up. Both logs list items in reverse chronological
order and are available from the Reports menu. To access the logs, follow these steps:
1. From the Main menu, type
4
, "Reports," and press
2. To view system events, type 2, "System Log," and press
3. To view traps, type 3, "Traps Log," and press
4. To return to the Main Menu, press
Control Management Packets
Use the Management Packet Control screen to enable or disable transmission of management packets
through any specific port on the 9160. If you disable a port, that limits that port to only network
traffic, the port cannot receive or send any packets that would manage the 9160. To access the
Management Packets Filter screen, follow these steps:
1. From the System menu type
8
, "Management Packet Control," and press
2. At the Management Packet Control screen, type the number for a port, then press
cycle between Enabled or Disabled.
3. To return to the System menu, press