CONFIGURATION MODULE ERRORS
DISPLAYED ERROR
DESCRIPTION
NO VALID CONFIGURATION
NO FLIGHT – OBTAIN
MAINTENANCE
There is a problem in the
system configuration that has
been detected on power up.
The display will be locked
and normal operation will not
be possible. If this message
is displayed during ground
operations flight is prohibited.
If this message is displayed
in flight continued flight by
reference to the standby
instruments will be required.
CONFIGURATION MODULE
AND INTERNAL CHECKSUM
FAILURE
NO FLIGHT – OBTAIN
MAINTENANCE
There is a problem in the
system configuration that has
been detected on power up.
The display will be locked
and normal operation will not
be possible. If this message
is displayed during ground
operations flight is prohibited.
If this message is displayed
in flight continued flight by
reference to the standby
instruments will be required.
CONFIGURATION MISMATCH
WILL LOAD MODULE DATA
FLIGHT OK- PRESS MIDDLE
BUTTON TO CONTINUE
This message is to provide
pilot awareness that there is
a mismatch between the
configuration module and the
PFD.
The configuration
module data will be used.
Flight and continued flight is
permitted. It is recommended
obtaining maintenance at the
next available opportunity.