Device > Setup RPD Modem window
REMOTE RW 232 DIAGNOSTICS
All that is required to perform remote diagnostics is a PC
running Windows
®
with a 28.8 kb modem or better, with
RaneWare
®
installed. This procedure calls a remote RW 232
site and operates it as if you are there.
1. Launch RaneWare.
2. Click the Device
button and select
any of the Offline
RW 232 devices.
3. Select
System >
System Setup.
Modem Init - Example string:
AT&FE0#CID=1#CLS=8#VBT=1#VLS=6L0
&F: Reset
E0: No Echo
#CID=1: Caller ID
#CLS=8: Voice Mode
#VBT=1: Set DTMF tone length 100ms
#VLS=6: Speaker Phone Mode
L0: Set speaker level to minimum
Dial Data - Example: AT#CLS=0DT
#CLS=0: Data Mode
DT: Dial Command
Dial Voice - Example: AT#CLS=8#VTS=
#CLS=8: Voice Mode
#VTS: Dial Voice Command
Dial DSVD - Example: AT-SSE=1DT
-SEE=1: DSVD Mode
DT: Dial Command
Answer Data - Example: AT#CLS=0A
#CLS=0: Data Mode
A: Answer
Answer Voice - Example: AT#CLS=8A
#CLS=8: Voice Mode
A: Answer
Answer DSVD - Example: AT-SSE=1#CLS=0A
-SEE=1: DSVD Mode
#CLS=0: Data Mode
A: Answer
Speaker Set - Example: A#SPK=1,6,0
#SPK=1,6,0: (mic on, speaker attenuation, mic gain)
Mic on=1; Mic Mute=0; Room Monitor=2
Speaker attenuation in 2 dB steps, (0-15) 0=Max; 6=-12 dB
Mic Gain (0-3) 0=0 dB, 1=6 dB, 2=9.5 dB, 3= 12 dB
MODEM SETTINGS
RPD 1 DEVICE EDIT
Answer after Rings - determines the number of ring signals
that will pass before the RPD 1 and modem will answer.
Answer Voice - determines if the RPD 1 and the attached
modem will answer in voice or data mode.
Answer When - Sets the auto answer mode.
RPD Device Edit window
System Steup Window