beautypg.com

Rane RPD 1 User Manual

Page 6

background image

Manual-6

Device > Setup RPD Modem window

REMOTE RW 232 DIAGNOSTICS

All that is required to perform remote diagnostics is a PC

running Windows

®

with a 28.8 kb modem or better, with

RaneWare

®

installed. This procedure calls a remote RW 232

site and operates it as if you are there.

1. Launch RaneWare.

2. Click the Device

button and select
any of the Offline
RW 232 devices.

3. Select

System >

System Setup.

Modem Init - Example string:

AT&FE0#CID=1#CLS=8#VBT=1#VLS=6L0

&F: Reset
E0: No Echo
#CID=1: Caller ID
#CLS=8: Voice Mode
#VBT=1: Set DTMF tone length 100ms
#VLS=6: Speaker Phone Mode
L0: Set speaker level to minimum

Dial Data - Example: AT#CLS=0DT
#CLS=0: Data Mode

DT: Dial Command

Dial Voice - Example: AT#CLS=8#VTS=
#CLS=8: Voice Mode

#VTS: Dial Voice Command

Dial DSVD - Example: AT-SSE=1DT
-SEE=1: DSVD Mode

DT: Dial Command

Answer Data - Example: AT#CLS=0A
#CLS=0: Data Mode

A: Answer

Answer Voice - Example: AT#CLS=8A
#CLS=8: Voice Mode

A: Answer

Answer DSVD - Example: AT-SSE=1#CLS=0A
-SEE=1: DSVD Mode
#CLS=0: Data Mode

A: Answer

Speaker Set - Example: A#SPK=1,6,0

#SPK=1,6,0: (mic on, speaker attenuation, mic gain)

Mic on=1; Mic Mute=0; Room Monitor=2
Speaker attenuation in 2 dB steps, (0-15) 0=Max; 6=-12 dB
Mic Gain (0-3) 0=0 dB, 1=6 dB, 2=9.5 dB, 3= 12 dB

MODEM SETTINGS

RPD 1 DEVICE EDIT
Answer after Rings - determines the number of ring signals

that will pass before the RPD 1 and modem will answer.

Answer Voice - determines if the RPD 1 and the attached

modem will answer in voice or data mode.

Answer When - Sets the auto answer mode.

RPD Device Edit window

System Steup Window