beautypg.com

Rane RPD 1 User Manual

Page 3

background image

Manual-3

RPD 1 PROGRAMMING & DIAGNOSTICS UNIT - REAR PANEL

POWER input connector: Use only a model RS 1 or other power supply approved by Rane. This unit is supplied with a

remote power supply suitable for connection to this input jack. This is not a telephone jack. The RPD 1 is a modem inter-
face
, not a telephone interface.
The power requirements call for an 18 VAC center-tapped transformer only. Using any other
type of unapproved supply may damage the unit and void the warranty.

RW 232 CONTROL - OUTPUT: This DB-9 male connects to downstream Rane RW 232 units. Refer to Appendix-Data

Connections on page Manual-10.

RW 232 CONTROL - INPUT: This DB-9 female connects to the RW 232 controller, computer, or other Rane RW 232

unit connected upstream. Refer to Appendix-Data Connections on page Manual-10.

RW 232 CONTROL - DEVICE ADDRESS: The RPD 1 requires setting of this RW 232 address. See page Manual-5.

USER DATA (RS-232): This DB-9 User Data Port connects the RPD 1 to the Room Controller’s program port or the

Room’s remote data transmission device, such as a PC. Refer to Appendix-Data Connections on page Manual-10.

MODEM (RS-232): This DB-25 male connects RS-232 data of the RPD 1 to the Modem’s RS-232 data connector (cable

provided).

MODEM MIC: This output section of the Euroblock connects to a 1/8" mini-plug Modem Mic input connector (cable

provided). Do not connect the ring on this mini-plug.

MODEM SPKR: This input section of the Euroblock connects to a 1/8" mini-plug Modem Speaker output connector (cable

provided). Do not connect the ring wire from the Modem.

AUDIO OUT: This same Euroblock delivers a balanced line level signal. AUDIO OUT typically connects to Port 6 Input

from the ECB 6.

AUDIO IN: This 5-pin Euroblock accepts a balanced line-level signal. AUDIO IN typically connects to the Port 6 Output

from the ECB 6.