beautypg.com

Rane RPD 1 User Manual

Page 2

background image

Manual-2

RPD 1 PROGRAMMING & DIAGNOSTICS UNIT - FRONT PANEL

AUDIO OUT SIG indicator: Lights when the Audio Out signal is above -25 dBu. Use to check signal flow.

AUDIO OUT OL indicator: Lights when the Audio Out signal is 2 dB before clipping.

AUDIO IN SIG indicator: Lights when the Audio In signal is above -25 dBu. Use to check signal flow.

AUDIO IN OL indicator: Lights when the Audio In signal is 2 dB before clipping.

STATUS—MODEM RX indicator: Lights when receiving data from Modem.

STATUS—MODEM TX indicator: Lights when transmitting data to Modem.

STATUS—MODEM AA indicator: Lights when Modem is sent an Auto Answer command.

STATUS—MODEM OH indicator: Lights when Modem is sent an Off Hook command.

STATUS—UDP RX indicator: Lights when receiving data to the User Data Port.

STATUS—UDP TX indicator: Lights when transmitting data from the User Data Port.

STATUS—ROUTE RW indicator: Lights when the Modem is routed through RW 232.

STATUS—ROUTE UDP indicator: Lights when Modem is routed through the User Data Port.

COM indicator: Flashes randomly when receiving valid data from the control system or PC. If the DEVICE ADDRESS is

not within a valid range (1-250), this LED flashes steadily at ½ second intervals.

POWER indicator: Lights when the processor is operational.

The modem to be used with the RPD 1 must meet these criteria:

1. 28.8 kbps minimum speed.
2. External
3. Hayes compatible.

RPD 1 MODEM COMPATIBILITY