Rane ECM 64e User Manual
Page 21
Manual-21
Hybrid Parameter List (HPL)
Hybrid Command
Data
Description
0
Dial DTMF Number
(char) string
Null terminated ASCII string, 20 (char) max
1
Dial Stored Number
1-6
Dial stored number (1 – 6)
2
Off Hook
1/0
1= Off Hook / 0 = On Hook
A ‘,’ within the DTMF number inserts a 1 second delay.
A non-digit within the DTMF number is allowed for separation (425.355.6000).
For Rev 1.2 or greater there are added special function DTMF dialing operators:
Operator
!1
Performs a 100 ms Flash Hook
!2
Performs a 500 ms Flash Hook
!3
Places the caller on Hold
!4
Removes the caller from Hold
Send Hybrid Command (92 hex)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $XX (where $XX = number of data bytes to follow including checksum)
Transmit $92 (command code)
Transmit Hybrid command
Transmit Data
Transmit the checksum
Get COMSTAT
Send MRP Table (93 hex)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $12 (where $12 = number of data bytes to follow including checksum)
Transmit $93 (command code)
Transmit 16 byte table
Transmit the checksum
Get COMSTAT
Get OPSTAT (00 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $02 (where $02 = number of data bytes to follow including checksum)
Transmit $00 (command code)
Transmit $FE (checksum)
Get STATUS
Get Checksum
Get COMSTAT