Troubleshooting guide – Wilbur Curtis TCC3S User Manual

Page 9

background image

9

SYMPTOM

POSSIBLE CAUSE

SOLUTION

TROUBLESHOOTING GUIDE

Difficulty priming the TCCS

tea dispenser.

Adjusting rod on mixing valve

is turned in too far.

Open up the valve 1/4 turn

counter clockwise.

Tea does not dispense from

faucet.

Water line is turned off.

Turn on the water line valve.

Only water flows from the

faucet, no tea.

1. Tea concentrate BIB is out

of product.

2. The tea BIB line is kinked.

3. The tea BIB line is

clogged.

4. The check valve in the tea

concentrate line may be

stuck closed.

5. The adjustment screw may

be turned in or closed.

1. Replace the tea concen-

trate BIB.

2. Trace the tea line and

straighten out kinked hose.

3. Blow out hose to clean

blockage or replace with a

new hose.

4. Loosen the clamps and

remove the check valve.

Clean or replace it.

5. Open the mixing valve to

resume product flow.

Faucet is dripping constantly.

1. The faucet seat cup may

have solid particles that

are keeping the faucet

from sealing.

2. There may be a tear or cut

in the seat cup.

3. Water pressure may be

too high.

1. Disassemble and clean

the seat cup (see cleaning

section).

2. Replace the seat cup.

3. Call CURTIS CARE for

instructions on adjusting

the water regulator.

Finished tea is weak.

1. The mixing valve is out of

adjustment.

2. The product check valve

may be stuck.

1. Open the mixing valve to

increase tea concentrate

flow.

2. Remove and clean the

check valve. Make sure

check valve is installed

with correct flow direction.