SYMPTOM
POSSIBLE CAUSE
SOLUTION
TROUBLESHOOTING GUIDE
Product flowing from the fau-
cet is too foamy or bubbly.
1. The clamps at the check
valve may not be tight.
2. The clamp on the Scholle
connector may be loose.
3. Tea concentrate product
may have air in the BIB.
4. The O-ring on the Scholle
connector is worn out.
1. Reconnect tubing and
tighten clamps.
2. Make sure the barbed
end of the Scholle fitting is
pushed in on the hose and
the clamp is tight.
3. Turn the BIB so the fitting
faces upward and open
the faucet until all the
bubbles are released.
4. Replace the worn O-ring
or install a new Scholle
connector.
DOs and DON’Ts
INSTALLATION
1. Do connect dispenser to a filtered waterline.
2. Do flush filters before connecting to dispenser.
3. Do sample finished drink before making ad-
justments.
4. Do make very slight drink adjustments then
sample.
5. Don’t forget to flush filters before installation.
6. Don’t make any pressure regulator adjust-
ments on dispenser (Do NOT attempt to
adjust the regulator. If a regulator adjustment
is required call CURTIS CARE).
7. Don’t forget to get sample approval from cus-
tomer.
OPERATION
1. Do fully activate faucet handle when dispens-
ing drinks.
2. Do clean & sanitize dispensing assembly
monthly.
3. Do keep dispenser primed with concentrate at
all times.
4. Do reload immediately when out of concen-
trate.
5. Do flush and clean lines regularly.
6. Don’t forget to clean & sanitize faucet seat cup
7. Do follow all cleaning and sanitizing proce-
dures. Remove and store tea concentrate if
dispenser will not be used for an extended
period of time (more than two days).