Program menus – Wilbur Curtis CBP User Manual

Page 4

background image

4

conditions, the three Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically extract

better with the A and B pulse setting. Decaf coffees typically extract better with the B pulse setting. High-Yield coffees

typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste

profile. Settings D and E are manual pulse counts. If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1

within 5ºF of set point and Cold Brew Lock disappears from the list of program selections.

When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.

Coffee Drip-out (Factory set to 2 minutes)

Press to Select. Press < or > to move to desired time. Settings are OFF, 1, 2, 3, 4 and 5 minutes. Press to Select

time.

Temperature (Factory set to 204°F)

Press to Select. Press < or > to move to desired temperature and then to set. Temperature is programmable from

170ºF to 204ºF in 2-degree increments.

Energy Save Mode (Factory set to OFF)

Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from

last brew. When feature is OFF, unit does not have the energy saving mode.

In the ON 140ºF position, temperature goes down to 140ºF, if unit has not brewed in 4 hours. This feature will save

energy by maintaining a lower temperature in the tank in periods of non-operation.

Brew Count Odom

Press to display total brew cycles. Press ex or Reset

Brew Count Total

Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.

Cold Brew Lock . . . (Factory set to 5º )

Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.

The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set

point for the Ready to Brew message, however, it will brew at any temperature.

Master Reset

Press to display Are You Sure?

Then < for Yes, > for No. Brewer factory defaults are then reset.

Service Call (Phone number Factory set to 1-800-000-0000)

Press to display number and change number or < to move place and EX to exit when complete. This number will be

displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1-2-3-4)

Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit

when complete.

Banner Name (Factory set to Curtis)

Press to display letters and change letters or < to move place and EX to exit when complete

This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks

disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.

P-Maintenance (Factory set to OFF)

Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.

Press to exit.

Beeper On/Off (Factory set to ON)

Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature al-

lows you to hear a short beep each time a button is pressed.

Energy Save Mode

Coffee

Drip-out

Temperature

Beeper On/Off

P-Maintenance

Banner Name

Access Code

Service Call

Master Reset

Cold Brew Lock

Brew Count Odom

Brew Count Total

Continued on Page 5

Program Menus