Replacement parts – Nexen FMCE-875 801474 User Manual
Page 13
13
FORM NO. L-20168-D-1112
REPLACEMENT PARTS
The item or balloon number for all Nexen products is used for part
identification on all product parts lists, product price lists, unit
assembly drawings, bills of materials, and instruction manuals.
When ordering replacement parts, specify model designation, item
number, part description, and quantity. Purchase replacement
parts through your local Nexen Distributor.
6. Clean the bearing bore of the Bearing Flange (Item 20) with
fresh safety solvent, making sure all old Loctite
®
residue is
removed (See Figure 12).
7. Apply an adequate amount of Loctite
®
680 to evenly coat
the outer race of the first new Ball Bearing (Item 30) on the
Stub Shaft (Item 11) and press the first new Ball Bearing
and Stub Shaft into the Bearing Flange (Item 20) until the
Ball Bearing is seated against the Retaining Ring (Item 58)
(See Figure 12).
8. Apply an adequate amount of Loctite
®
680 to evenly coat the
outer race of the second new Ball Bearing (Item 30) and press
the second new Ball Bearing onto the Stub Shaft (Item 11)
and into the Bearing Flange (Item 20) until the Ball Bearing
is seated against the Retaining Ring (Item 58) (See Figure
12).
9. Reinstall the Retaining Ring (Item 35) (See Figure 12).