Figure 6-4
Chain Replacement
6.6 Storage
6.6.1
ER models with vented oil cap assemblies should be stored with the cap oriented up to prevent oil
leakage.
6.6.2
The storage location should be clean and dry.
6.7 Outdoor
Installation
6.7.1
For hoist installations that are outdoors, the hoist should be covered when not in use.
6.7.2
Possibility of corrosion on components of the hoist increases for installations where salt air and high
humidity are present. Make frequent and regular inspections of the unit's condition and operation.