Bradford White U-TW4-75S-76R-3N User Manual
Page 7
Specifications
Venting Specifications:
Through the Wall
Terminating
# of
Elbows
Maximum
Length ft (m)
Minimum
Length ft (m)
3" Diameter (7.6 cm) PVC Vent Connector Lengths
1
45 (13.7)
2 (.6)
Through the Wall
2
40 (12.2)
2 (.6)
Through the Wall
3
35 (10.7)
2 (.6)
Through the Wall
4
30 (9.1)
2 (.6)
Through the Wall
Terminating
# of
Elbows
Maximum
Length ft (m)
Minimum
Length ft (m)
4" Diameter (10.2 cm) PVC Vent Connector Lengths
1
175 (53.3)
10 (3.1)
Through the Wall
2
170 (51.8)
10 (3.1)
Through the Wall
3
165 (50.3)
10 (3.1)
Through the Wall
4
160 (48.8)
10 (3.1)
Through the Roof
0
50 (15.2)
7 (2.1)
Through the Roof
1
45 (13.7)
7 (2.1)
Through the Roof
2
40 (12.2)
7 (2.1)
Through the Roof
3
35 (10.7)
7 (2.1)
Through the Roof
0
180 (54.9)
15 (4.6)
Through the Roof
1
175 (53.3)
15 (4.6)
Through the Roof
2
170 (51.8)
15 (4.6)
Through the Roof
3
165 (50.3)
15 (4.6)
Through the Wall
5
155 (47.2)
10 (3.1)
Through the Roof
4
160 (48.8)
15 (4.6)
Vent Tables
Page 7
7