Specifications

Venting Specifications:

Through the Wall

Terminating

# of

Elbows

Maximum

Length ft (m)

Minimum

Length ft (m)

3" Diameter (7.6 cm) PVC Vent Connector Lengths

1

45 (13.7)

2 (.6)

Through the Wall

2

40 (12.2)

2 (.6)

Through the Wall

3

35 (10.7)

2 (.6)

Through the Wall

4

30 (9.1)

2 (.6)

Through the Wall

Terminating

# of

Elbows

Maximum

Length ft (m)

Minimum

Length ft (m)

4" Diameter (10.2 cm) PVC Vent Connector Lengths

1

175 (53.3)

10 (3.1)

Through the Wall

2

170 (51.8)

10 (3.1)

Through the Wall

3

165 (50.3)

10 (3.1)

Through the Wall

4

160 (48.8)

10 (3.1)

Through the Roof

0

50 (15.2)

7 (2.1)

Through the Roof

1

45 (13.7)

7 (2.1)

Through the Roof

2

40 (12.2)

7 (2.1)

Through the Roof

3

35 (10.7)

7 (2.1)

Through the Roof

0

180 (54.9)

15 (4.6)

Through the Roof

1

175 (53.3)

15 (4.6)

Through the Roof

2

170 (51.8)

15 (4.6)

Through the Roof

3

165 (50.3)

15 (4.6)

Through the Wall

5

155 (47.2)

10 (3.1)

Through the Roof

4

160 (48.8)

15 (4.6)