background image

Specifications

Thermal well ECO Limit

Residential 188°F (87°C), Commercial 199°F (93°C)

Residential Temperature
Set Point Range

60°F (16°C) to 160°F (71°C) (Approximate temperatures)

Blower Temperature Switch

Normally closed, opens @ 165°F (74°C), auto reset @ 130°F (54°C).

Blower

U2TW75 and UTW475S Models:
115VAC, 60Hz, 3.1 amps, 3000 RPM, 68 [email protected]" W.C.

Pressure switch

U2TW75 and UTW475S Models:
Normally open, closes on vacuum increase @ -1.28, opens on vacuum decrease @ -1.25

Power supply

Dedicated 115VAC, 60 Hz, 15A

Approved Gas Type

Natural.

Venting System

Power vent through the wall or vertical through the roof

Approved Vent Materials

PVC, CPVC or ABS

Gas Supply Pipe

Minimum 1/2" NPT (schedule 40 black iron pipe recommended)

Minimum Clearance
for Servicing

18" from top, 24" from front, 4" sides and rear.

Water Supply Pressure

150 PSI maximum allowable working pressure. Check local codes for supply pressure

Gas Pressure

6.0" W.C. min. and 14.0" W.C. max.

Commercial Temperature
Set Point Range

80°F (27°C) to 180°F (82°C) (Approximate temperatures)