U TTW SERVICE PROCEDURE X

Safety Circuit Voltage Trace

Safety Circuit Voltage Trace

WARNING

115 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

Position gas control switch to the “ON”

position and adjust thermostat dial to call

for heat, Is there 10 to 13 VAC between red

wire leading to blower temperature switch

and green ground wire?

Blower must be running during this

voltage check

(see photo 26).

Red wire leading to

blower temp. switch

Green ground wire

26

Yellow wire

leading from

pressure switch

Y

Is there 10 to 13 VAC between yellow wire

leading from pressure switch and green

ground wire

(see photo 26)?

Do you hear or can you see

the igniter sparking?

Y

Y

Is LED on gas valve flashing the

“heartbeat” code (alternating

bright/dim)

N

Safety circuit

voltage is OK.

No voltage from gas control,

call for technical support.

Y

NOTE: This procedure assumes a cool tank.

Verify 115VAC to gas

control (see page 32).

Is there continuity

through blower

temperature switch

(see page 24)?

Y

Check for loose or

broken wire connection

at switch terminals.

N

N

Determine cause of blower

temperature switch activation

and correct.

Check igniter/sensor

(see page 19).

is igniter/sensor OK?

If burner does not light,

observe LED flash code on

gas valve and refer to

troubleshooting section on

page 12.

N

N

Page 31

25

Step 1.

Remove three screws (Phillips
Screw driver) from control
access cover on blower and
remove cover (see photo 24
and 25).

Faulty cord set or

gas control.

Y

Correct igniter/

sensor problem.

Control Access

Cover Screws

24

R

31