LED Status

Control Status

Probable Cause

Service Procedure

Five flashes

and three

second

pause.

Thermostat well fault.

1. Damage to the

thermowell wire.

2. Thermowell

sensor resistance

out of range.

See page 14.

Six flashes

and three

second

pause.

Chamber door

temperature sensor out

of specification.

Possible electrical

short.

1. Chamber door

temperature sensor

out of calibration.

2. Possible

electrical short.

See page 18.

Seven flashes

and three

second

pause.

Gas valve electronic

fault detected.

1. Control needs to

be reset

2. Control is wet or

physically damaged

1.Turn gas control knob

to "OFF" position and

then follow lighting

instructions.

2. Replace gas control,

see page 16.

Eight flashes

and three

second pause

False pilot flame

present.

Pilot valve stuck in

open position.

Replace gas control, see

page 16.

Ten flashes

and three

second pause

Insufficient combustion

air detected. Reset

system.

Insufficient

combustion air.

See page 19 and 23.

Gas Control Troubleshooting