beautypg.com

Bradford White U-65T-55FR-3N User Manual

Page 21

background image

Step 1.

Remove outer jacket door.

Step 2.

Disconnect white wire leads from resettable thermal switch.

Step 3.

Using a multimeter capable of measuring continuity (Ohms),

place one probe of meter on one of the brass connection tabs of

the resettable thermal switch, and the remaining probe on the

other connection tab.

Step 4.

If continuity is indicated, the switch is closed, allowing millivolt current to pass.

Step 5.

If continuity is not indicated, the switch is open, possibly due to an over heating condition. The switch is

designed to open at predetermined temperatures. An open switch can be reset by depressing the red colored

button located at the center of the switch. The overheating condition must be determined prior to putting the

water heater back in service.

RESETTABLE THERMAL SWITCH CONTINUITY TESTING

PROBABLE CAUSE FOR RESETTABLE THERMAL SWITCH ACTIVATION

PROBABLE CAUSE

CORRECTIVE ACTION

Burner Failure

1. Inspect burner per SERVICE PROCEDURE

ED-VI

2. Replace burner per SERVICE PROCEDURE

ED-VI

Weak switch or switch

out of calibration.

1. Replace resettable thermal switch

Flammable vapor incident

1. Replace water heater.

SERVICE PROCEDURE ED-VII

Resettable Thermal Switch

Testing and Replacement

Page 21

21