Software Controlled STORE/RECALL Cycle

The software controlled STORE/RECALL cycle follows.

[11, 12]

Parameter

Alt

Description

25 ns

45 ns

Unit

Min

Max

Min

Max

t

RC

t

AVAV

STORE/RECALL Initiation Cycle Time

25

45

ns

t

SA

[11]

t

AVEL

Address Setup Time

0

0

ns

t

CW

[11]

t

ELEH

Clock Pulse Width

20

30

ns

t

HACE

[11]

t

ELAX

Address Hold Time

20

20

ns

t

RECALL

[11]

RECALL Duration

20

20

μs

Switching Waveforms

Figure 10. CE Controlled Software STORE/RECALL Cycle

[12]

t

RC

t

RC

t

SA

t

SCE

t

HACE

t

STORE

/ t

RECALL

DATA VALID

DATA VALID

6

#

S

S

E

R

D

D

A

1

#

S

S

E

R

D

D

A

HIGH IMPEDANCE

ADDRESS

CE

OE

DQ (DATA)

Notes

11. The software sequence is clocked on the falling edge of CE without involving OE (double clocking abort the sequence).
12. The six consecutive addresses must be read in the order listed in the Mode Selection table. WE must be HIGH during all six consecutive cycles.