Changed settings on the thermostat A common problem is not waiting long
改变恒温器设置 enough for the internal timers to complete
their timed delay. These timers can be
manually overridden. Follow the
manufacturer’s instructions.

常见的问题是没有等待足够长的内

部定时器定时延迟完成。这些定时器可以
手动覆盖。按照制造商的自动调温器指示。

Unit Does Not Start-up 主机不启动机器

Power Switch Light is Off 电源开关灯不亮

Possible Cause
可能的问题 Solution 解决方案

Switch not on 开关没开 Turn on switch 打开开关

No power to outlet 插座无电源插座 Check circuit breaker and wiring 检查断路器

Unit not plugged in 机器没有插上 Plug in the unit 插上机器电源

Power Switch Light is On and the Thermostat Light is Off
电源灯亮着,恒温器灯不亮

Possible Cause 可能的问题 Solution 解决方法

No power to thermostat Check wiring for loose broken or frayed
恒温器无电源 connections
检查接线是否松动,断裂连接
Check transformer for 24v output

检查温控器 24V 变压器输出电压

Power Switch Light is On and the Thermostat Light is On

电源开关指示灯亮起,恒温器灯亮

Possible Cause 可能的问题

Solution 解决方法


Thermostat is not set up properly Check thermostat set up in the guide.

检查温控器设置指南。

温控器设置不正确 Press fan ON switch to check evaporator fan
only.

按风扇开关,只检查蒸发器风扇。