The HPM requires minimal routine maintenance, apart from checking
the connections and overall operation periodically.
Routine checks
During use, check the following:
•
Check cables for signs or wear or damage. Replace as necessary.
•
Periodically, check the fixings securing the HPM to the head.
•
Check that all cables are connected properly.
Cleaning
During normal use the only cleaning required should be a regular wipe
over with a dry, lint-free cloth. Dirt accumulated during storage or
periods of disuse may be removed with a vacuum cleaner. Particular
attention should be paid to all connection ports.
Technical Specification
Dimensions
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.68 kg (3.7 lb)
Height (excl. PSU) . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mm (4.7 in.)
Width (excl. integral mounting bracket) . . . . . . . . . . . 118 mm (4.6 in.)
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 mm (8.7 in.)
Power
Power input and Current rating . . . . . . . . . . . . . . . . . . 12V DC / 2.5A.
Power supply (to power supply unit) . . .100-240V AC, 50/60 Hz, 1.5A
Shock insulation . . . . . . . . . . . . . . . . . . . . . . . Class I (basic insulation)
Environmental
Temperature range (operation). . . . . . . . 0°C to +30°C (32°F to +86°F)
Data Specification
Supported data protocol . . . RS422 (Vinten Radamec D1 data packet)
RS232 available as a factory upgrade only.
Genlock Specification
Composite Video (CVBS) and S-Video (Y/C):
SDTV . . . . . . . . . . . . . . . . SMPTE 170M (NTSC), ITU-R BT.140 (PAL)
Component Video (YP
B
P
R
/GBR):
SDTV . . . . . SMPTE 125M, SMPTE 267M, ITU-R BT.601 (480I, 576I)
EDTV . . . . . . . . . . . . . . . . . . . . . . . . . . . .ITU-R BT.1358 (480P, 576P)
HDTV . . . . . . . . . . . . . SMPTE 296M (720P), SMPTE 274M (1080I/P)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMPTE RP211 (1080PsF)
Technical specifications are subject to change without notice.
WARNING! Risk of electric shock. Always check cables
for signs of damage. Damaged cables can cause personal
injury and/or damage the equipment.
WARNING! Risk of electric shock. Always disconnect and
isolate the product from the power supply before cleaning.