Fusion FHR-120 robotic pan and tilt heads
34
Troubleshooting
Fault
Check
See
Power supplied, but the
camera cradle is not
moving.
Check that the camera cradle lock is
disengaged.
Locking the camera
cradle on page 29
Head not operating.
Check that the power switch is ON.
Powering up on
page 29
Ensure that the power and Ethernet
cables are connected and secure.
Power and Ethernet
connections on
page 20
Check power supply to head. Check that
power is being supplied from the
pedestal, height drive or studio supply.
Check the head fuses and replace as
necessary. The head requires two T6.3A
fuses.
Changing a fuse on
page 33
Camera and payload
moving too far on the
pan and tilt axis.
Check the pan and tilt limits using the
Fusion Setup and Test configuration
software tool.
Setting the pan and
tilt movement limits
on page 26