5) Reinstall the strainer in the valve inlet and replace the tubing and tighten the compression

nut. Double wrench to prevent damage and leaks.

6) Disconnect the water line on the outlet of the solenoid valve.
7) Remove the orifice from the copper tube and make sure this small opening is unplugged.
8) Replace the orifice and reconnect the outlet water line. Double wrench to prevent leaking.
9) Reinstall the in-line strainer and reconnect the inlet water line. Double wrench to prevent

leaking.

10) Turn on water supply and reconnect electrical power to the humidifier.
11) Check to be sure the water supply tube is aimed at the center of the distribution tray between

the two center holes. This will ensure even distribution off water across the entire tray and
equally into each of the six holes, thereby evenly wetting the entire surface of the drip pad.


Water Line Maintenance Detail

Figure 8.0