NOTE: In all mounting arrangements make sure the humidifier is level and plumb in all
directions
.
3) Install a ¼”water line from the water supply into the opening on the top of the humidifier.
Use flexible tubing to allow the unit to be rotated. A shut-off valve (not provided) is
recommended to isolate the humidifier from the water system when needed.
4) Install a ½” flexible drain line from the bottom of the humidifier to an open drain or connect
into the drain line from the cooling unit.
5) Install the humidistat on the wall where it is open to the cellar and can be read easily,
approximately 60 inches above the floor.
6) Connect the wires from the humidifier to the terminals on the transformer. Plug the
transformer into a 120v standard outlet.
Stand-Alone Humidifier Mounting (Typical)
Figure 5.0