beautypg.com

Controller functions – Vintage Cellars SC Series WhisperKOOL User Manual

Page 20

background image

SC

033114

Page 18 | 1-800-343-9463

CONTROLLER FUNCTIONS

Button/Symbol

Normal Functions

ON/OFF

Press and hold the on/off button for approximately 3 seconds to turn the unit on or off.

Note: This does not disconnect power from the unit. In order for the power to be shut off from

the unit, the power cord must be unplugged from the wall receptacle.

This button also serves as an escape button.

Up and Down

Use these buttons to scroll up or down a menu.

Press and hold the up button for approximately five seconds to manually start the Anti-

Frost sequence. The Anti-Frost sequence will begin, but only if the evaporator is below

40

°F

. If the evaporator is above 40

°F

, the display will blink three times, signalling that an

Anti-Frost cycle is not needed, and the unit will continue normal operation.

SET

Press the “SET” button once to view the set point, temperature of the evaporator,

condenser, and actual bottle temperature as well as any alarms.

Once the “SET” button is pressed “SEt” will be displayed. Press the up or down arrows to

scroll through Pb1, Pb2, Pb3.

SEt Set Point

Pb1 Liquid Temperature
Pb2 Evaporator Coil Temperature
Pb3 Condenser Coil Temperature

Press the “SET” button again to view any of these values.

To change the set point, press the “SET” button. When “SEt” is displayed on the screen,

press the “SET” button once more. Use the up and down arrow buttons in order to

change the value until the desired set point is reached.

Hold the “SET” button for approximately 5 seconds to enter the CPSM (Customer

Preference Selection Mode) menu. (CPSM detail on next page)

Snowflake Constant: The unit is in cooling mode and the compressor is running.

Blinking: The unit is calling for cooling, but must wait 5 minutes before restarting the

compressor. This 5 minute delay serves as an anti-short cycle for the compressors protection.

Dripping Snowflake Unit is in Anti-Frost mode. The evaporator and condenser fans are running to evaporate any

frost which may have formed on the evaporator coil.

Fan The evaporator and condenser fans are on.