beautypg.com

Preparing the installation location, Through-the-wall – Vintage Cellars SC Series WhisperKOOL User Manual

Page 14

background image

SC

033114

Page 12 | 1-800-343-9463

Minimum Tools Needed

Locate the desired installation location (no lower than 18” inches from the

ceiling). Using a stud finder, locate the studs on either side of the center point,

and mark them with vertical lines.

Using a level and a pencil, mark a horizontal line on the wall between the two

studs, no less than 1.5” and no more than 18” from the ceiling.

Using a ruler or measuring tape, measure 16” down (2000/3000/4000) or 22.75”

down (6000/8000), and mark another horizontal line parallel to the first one.

The unit is designed to fit between two studs that are 16” apart on center,

enabling the unit to fit in the 14.5” horizontal space.

Using a saw, cut along the uppermost horizontal line until your saw reaches

the stud. Turn the saw around, inserting it into the cut that has just been

made, and cut toward the opposite stud so that there is a clean horizontal cut

between the two studs. Be careful not to cut into the studs themselves.

Make the second horizontal cut from stud to stud on the line 16” below the

first cut.

Once the horizontal lines have been cut, make vertical cuts using the inside

edge of the studs as a guide. Once both vertical cuts have been made, there

should be rectangular hole in the sheetrock. Make the same hole on the other

side of the wall. Using a nail, mark all four corners of the first hole by making

nail holes through the sheetrock. Connect the holes with a pencil mark and cut

on the other side of the wall.

Sheetrock alone cannot support the weight of a cooling unit. Therefore, it

is necessary to frame the hole that has just been cut with upper and lower

supports. These supports also provide solid material for the mounting bracket

screws.

Using two 2x4s at 14.5” in length and eight 6d nails, secure the upper and

lower supports to the right and left studs, just inside the sheetrock. Make sure

that the internal height remains at 16” (2000/3000/4000) or 22.75” (6000/8000)

so that the WhisperKOOL unit will fit snugly through the framed cut-out.

Hammer

Saw

Screwdriver

Level

PREPARING THE INSTALLATION LOCATION

Through-the-Wall