Special operating instructions – Smart Power Systems Liberator Series User Manual
Page 35
Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 34 of 54
b. Note the
y and n labels below the Mode and On/Off switches. Press the On/Off
switch to answer “yes” and proceed to the next screen, or press Mode to answer
“no” and proceed to the oil temperature display.
Step c: Press On/Off to
answer “yes” and
override the shutdown.
Example of Command & Control Center
in hot oil fault override confirmation
Figure 23
c. If your answer was “yes” in the previous step, the confirmation screen shown in
Figure 23 will be displayed. Again note the y and n labels below the Mode and
On/Off switches. Press the On/Off switch to answer “yes” and override the
shutdown. Press Mode to answer “no” and proceed to the oil temperature
display.
Note: If you override the system and command it to operate at oil temperatures
above 175
°F, the system output power may degrade and you will void the
system’s warranty.
Special Operating Instructions
For A.C. Modular Generator System
Cold Weather Procedure:
It is strongly recommended that the generator PTO be engaged prior to leaving a heated
garage or fire station in cold weather. The system will generate enough heat to keep its
hydraulic fluid viscosity low enough for proper operation, in all but the most extremes of
low ambient air temperatures.
If the generator system is “started” when the hydraulic oil temperature is below 40
°F, the
following message will be displayed on the Command & Control Center (reference Figure
24):