Smart Power Systems Liberator Series User Manual
Page 11
Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 10 of 54
MODEL OF
GENERATOR
LI-15
LI-20
LI-25
Oil Cooler
Dimensions (Core)
7.5”D x 18.9” W x 27.25”L
7.5”D x 18.9” W x 32.3”L
7.5”D x 18.9” W x 32.3”L
Fan
Voltage
Amperage
12 Inch Pusher
12 Volts DC
22 Amps
16 Inch Pusher
12 Volts DC
22 Amps
16 Inch Pusher
12 Volts DC
22 Amps
Filter
10 Micron
10 Micron
10 Micron
Hydraulic Oil
(recommended)
(alternate)
Maximum Viscosity
Minimum Viscosity
Op. Temp. range
(deg. F.)
Dexron III
ISO Approved Hydraulic
Fluid
4650 SUS (1000 cSt)
55 SUS (10 cSt)
-13° F to 195° F
Dexron III
ISO Approved Hydraulic
Fluid
4650 SUS (1000 cSt)
55 SUS (10 cSt)
-13° F to 195° F
Dexron III
ISO Approved Hydraulic
Fluid
4650 SUS (1000 cSt)
55 SUS (10 cSt)
-13° F to 195° F
Hoses
Motor Inlet
All Others
JIC STD
4000 psi, SAE
1250 psi, SAE
SAE
6000 psi, SAE
1250 psi, SAE
SAE
6000 psi, SAE
1250 psi, SAE
Fittings
SAE SAE SAE
Dry Weight
(without pump)
485 lbs
580 lbs
715 lbs
Dimension of Tray
Asm.
40.5” L x 19” W x 22” H
(Including Reservoir)
46” L x 19” W x 22” H
(Including Reservoir)
48” L x 19” W x 22” H
(Including Reservoir)
Ambient Operating
Temperature Range
0
°F to 120°F 0°F to 120°F 0°F to 120°F
Note : The recommended PTO ratio is 1.29 : 1 (129%).
The recommended engine idle speed with this PTO is 750 RPM.
This will result in a 968 RPM pump drive input, thereby insuring 5KW
of available power at engine idle. If full output is required at idle speed, then a higher PTO
ratio must be chosen to create 1200 RPM pump drive at idle speed; however care must
be taken to prevent higher engine speeds from creating a pump speed that exceeds the
pump’s maximum speed.