A. C. MODULAR GENERATOR SYSTEM

Page 13 of 54

WARNING:


Do not install hose ends until proper hose length has been determined.

Never install a hose in a location where it will rub against an abrasive surface or
sharp edge or corner.

Do not position hoses with tight bend radii. Consult the hose manufacturer’s
installation guidelines. Tight bends may kink and cause serious damage to the
system and will void the system’s warranty.

Use caution when tightening the hose ends to prevent the hose from becoming
twisted.

Never install a 90° fitting at the pump inlet or outlet. Avoid the use of flow
restricting fittings.

Do not form loops in the hose that may collect air or kink. Run hoses as straight as
possible (but not taut) between connections.

Do not exceed hose lengths of 20 feet.


6.

SPS models LI-15, LI-20, and LI-25 can be mounted on top of a vehicle, in the
open, without requiring any additional coverings. Reference Figure 3, Figure 4 and
Figure 5 for the minimum clearances around the perimeter of the generator tray
assembly. Also, do not position any obstructions directly in front of the system’s oil
cooler. If the system cannot be installed without maintaining the minimum
clearances as indicated, or if you have any questions relative to the installation of
these systems, contact Smart Power

®

Systems at (231) 832-5525.


WARNING: Additional considerations must be made for mounting the XRT
reservoir and the other rescue tool components. Reference the
XRT manual for further instructions PRIOR to installation
.