beautypg.com

Operation – Smart Power Systems Liberator Series User Manual

Page 30

background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 29 of 54

Operation

For A.C. Modular Generator System

(Reference XRT Manual for Operation Instructions of rescue tool pump system)


1A. The Command & Control Center will show the generator’s output voltage,

frequency, current, and system run time whenever the Command & Control Center
is in the Normal mode. To access Normal mode, press the Mode switch repeatedly
until the correct information is displayed (reference Figure16A).

Example of Command & Control Center in Normal Mode

Figure 16A


1B.

When system current draw is 100 amps or more, the current will be displayed in the
‘HOURS’ window instead of the AMPS window. The designator ‘L1’ or ‘L2’ will be
shown in the corresponding AMPS window (reference Figure16B). If BOTH L1 and
L2 are over 100 amps, then each of the two currents will be alternately, over about
3 seconds, shown in the HOURS window.

Example of Command & Control Center in 100+ AMP Mode

Figure 16B


2.

The PTO driving the SPS hydraulic pump must be engaged for the system to
generate electricity.