Installation
As with any weighing equipment, the accuracy of the scale is dependent on the 
installation. The following points must be adhered to when installing the MAS-P 
Animal Scale. 
3.1 All Installations
In all installations, the scale must be level to ensure proper operation. All MAS-P 
Animal Scales are equipped with a bubble level (located on top the base frame – see 
Figure 3-1). Ensure the bubble is fully inside the circle marked on the top of the level. 
3.2 Permanent Installation
Rice Lake Weighing Systems recommend a concrete foundation (piles or piers) for 
permanent installations. The foundation must be able to support the gross weight of 
the scale (scale dead weight plus scale capacity), and the piles or piers must be 
situated directly under the load cell stands (see shimming location in Figure 3-1). The 
foundation must not be subject to distortion or motion due to frost action. A qualified 
local professional should be consulted to recommend the proper size of foundation for 
the location. Foundation dimensional requirements are available from the dealer or 
Rice Lake Weighing Systems. Requirements may vary from one Weights and 
Measures jurisdiction to another, please contact the local office. 
3.3 Portable Installation
The MAS-P is ideal for use in many locations. Simply load and unload the scale as 
described in the Section 1.3 on page 7. Locate the scale in as level a location as 
possible, and shim (with wood or metal shims) under the load cell stands to ensure the 
scale is level as described above. Please contact the local Weights and Measures 
office regarding the moving of the scale to ensure the validity of the certification.
Scale Cable
Bubble Level
Figure 3-1. Shim/Load Cell Stand Locations
3.4 Switching Between Modes
3.4.1
Converting to Weigh Mode
1. Place the scale in as level a location as possible. Ensure there are no obstructions
under the deck that would affect weighing accuracy. Check the bubble level. Use 
shims or timbers to ensure the scale is as close to level as possible. 