Wiring diagram load cells in hazardous areas – Rice Lake Load Cells - Wiring for Hazardous Environments User Manual
Page 38

Control Drawing 53414
35
RL35023-N5
RL90000
RL20000B
RL20001-T10
RL30000
RL75058B
RL75223B
RL75016
RL70000C
RL75040
RL30000W
RL35023SS
RL1521
RL35023
RL75016SS
-
+
-
+
-
+
NONINCENDIVE FOR CLASS I,II,III, DIVISION 2, GROUPS A,B,C,D,F
,G
VMAX = 12V CI=0
IMAX = 100MA LI=0
VMAX = 12V CI=0
IMAX = 100MA LI=0
VMAX = 12V CI=0
IMAX = 100MA LI=0
IMAX = 100MA LI=0
VMAX = 12V CI=0
IMAX = 100MA LI=0
VMAX = 12V CI=0
IMAX = 100MA LI=0
VMAX = 12V CI=0
NOTE: MUST BE INST
ALLED PER THE
NA
TIONAL ELECTRICAL CODE.
350 OHM
700 OHM
1 TO 8 700 OHM CELLS.
1 TO 4 350 OHM CELLS
LOAD CELL MODEL NUMBERS:
BOX
OPTIONAL
JUNCTION
-OUT
+OUT
+SEN
-SEN
LOAD CELL
-EXC
+EXC
HAZARDOUS LOCA
TION
REMOTE
SENSE (RECOMMENDED)
OUTPUT
SIGNAL, mV
LOAD CELL
EXCIT
A
TION SUPPL
Y
DRAWING REVISIONS MUST BE APPROVED
BY F
ACTOR
Y MUTUAL PRIOR TO RELEASE.
SCALE
TREA
TMENT
ANGLE
3 PLC
2 PLC
TOL.
DECIMAL
DRAWING TOLERANCES
TITLE
SHEET OF
DWG NO
THIS DRAWING AND ALL INFORMA
TION CONT
AINED HEREIN IS AND REMAINS
THE PROPER
TY OF RICE LAKE WEIGHING SYSTEMS INC. AND IS CONFIDENTIAL.
IT IS SUBMITTED AND MA
Y BE USED ONL
Y IN CONNECTION WITH RICE LAKE
WEIGHING SYSTEMS' PROPOSAL AND/OR ITS CUSTOMERS' ORDERS. IT SHALL NOT BE
DISCLOSED TO OTHERS OR COPIED WITHOUT RICE LAKE WEIGHING SYSTEMS' SPECIFIC
WRITTEN CONSENT AND SHALL BE IMMEDIA
TEL
Y RETURNED UPON REQUEST
.
REVISION
REVISIONS
REV
REFERENCE
INIT
DA
TE
ALL THREADS TO BE CLASS 2
UNLESS OTHER
WISE SPECIFIED
ALL DIMENSIONS APPLICABLE AFTER TREA
TMENT
UNLESS OTHER
WISE SPECIFIED
DO NOT SCALE
DRAWING
SURF
ACE
FINISH
MA
TERIAL
THIRD ANGLE PROJECTION
UNITS TO BE INCHES
FOR RL
WS
USE ONL
Y
RICE LAKE WEIGHING SYSTEMS
MFG.ENG.
DR.BY
APPROVED
DES.ENG.
APPROVED
CKD.
WIRING DIAGRAM
LOAD CELLS IN HAZARDOUS AREAS
53414
1:1
29
---
---
---
---
SEE NOTES
NONE
C
SBD 10/28/99
0
11
10
9