0 scale calibration – Rice Lake Bariatric/Handrail Scale (240-10) User Manual
Page 17

Handrail Scale Technical and Operating Instructions - Scale Calibration
13
5.0
Scale Calibration
Before you can calibrate the scale, verify and set all scale parameters which are noted in “Scale Configuration”
on page 7.
Remove the configuration/calibration jumper (see page 7). Turn the scale on. While
StArt
is displayed, press and
hold both the
Kg-Lb
key and the
REWEIGH
keys until
CAL
is displayed.
To do a calibration on the scale, the scale must be turned off.
NOTE: The calibration weight must be no less than 60 lb (28 kg) and no more than 300 lb (135 kg).
The following chart illustrates the calibration procedure.
Table 5-1. Calibration Menu
Step
Function
Display
Available Parameters
1
Turn the scale on.
While START is
displayed, press and
hold the Kg-Lb and
REWEIGH keys until
CAL is displayed.
Enters into calibration
mode
StArt
The scale automatically advances to
Step 2.
2
Cal mode entered
CAL
To advance to the next step, press the
REWEIGH key.
3
Sets the value of the
calibration weight
you are going to use
for calibrating the
span value of the
scale.
LOAd <-> XXX.X
Use the numeric data entry (explained in
“Numeric Data Entry” on page 8) to set a
calibration weight.
To advance to the next step, press the
REWEIGH key.
4
CLEAr
Clear the platform and be sure of the
scale’s stability.
To advance to the next step, press the
REWEIGH key.
5
Calibrate Zero
- - - - -
PUT<->XXXX
Place the requested weight on the scale.
This will display for a few seconds.
To advance to the next step, press the
REWEIGH key.
6
Calibrate Span
CAL
FAC tOr <-> X.XXX
This will be displayed for a few seconds
and shows the current calibration factor.
To advance to the next step, press the
REWEIGH key.
7
SAvE
To save the new calibration, press the
REWEIGH key.
To exit without saving the calibration
press the ZERO key.
8
dONE
The scale displays that it has saved that
calibration value and automatically
advances to the last step.
9
StArt
The scale reboots.
10
Con En
Replace the configuration jumper.