Serial Commands
87
9.1.2
Reporting Commands
Reporting commands send specific information to the
serial port. The commands listed in Table 9-2 can be
used in either setup mode and normal mode.
Table 9-2. Reporting Commands
Command
Function
DUMPALL
List all parameter values
SPDUMP
Print setpoint configuration
VERSION
Write
920i
software version
HARDWARE
Lists option cards installed in slots 1–14.
See Section 10.1.2 on page 104 for more
information about using the HARDWARE
command.
XE
Returns a10-digit code representing any
error conditions currently shown on the
front panel. See Section 10.1.4 on
page 105 for more information.
9.1.3
Clear and Reset Commands
The following commands can be used to clear and
reset the
920i
:
PCLR
: Program clear. Erases the loaded user
program (setup mode only).
RS
: Reset system. Resets the indicator without
resetting the configuration.
RESETCONFIGURATION
: Restores all configuration
parameters to their default values (setup mode
only). The
RESETCONFIGURATION
function can
also be initiated by pressing the
Reset Config
softkey under the VERSION menu. Use the
up
key to select
Clear entire indicator configuration
, then
press
ENTER
to reset the indicator.
NOTE:
All load cell calibration settings are lost when the
RESETCONFIGURATION command is run.
9.1.4
Parameter Setting Commands
Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 9-3 through 9-12).
Current configuration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:
command
Most parameter values can be changed in setup mode
only; setpoint parameters listed in Table 9-6 on
page 92 can be changed when in normal weighing
mode.
Use the following command syntax when changing
parameter values:
command=value
, where
value
is either a number or a parameter value. Use no spaces
before or after the equal (=) sign. If you type an
incorrect command, the display reads
??
.
For example, to set the motion band parameter on
Scale #1 to 5 divisions, type the following:
SC.MOTBAND#1=5D
For parameters with selectable values, enter the
command and equal sign followed by a question
mark:
command=?
to see a list of those values.
The indicator must be in setup mode to use this
function.
NOTE: Some parameters are valid only if other parameters or
parameter values are specified. See the configuration menus
in Section 3.2 on page 22 for information about parameter
dependencies. Restrictions for front-panel configuration also
apply to serial command configuration.
Command
Description
Values
SC.SRC#n
Scale source
Specify scale source as: SC.SRC#n = y, z.a
y Scale type:
A
A/D scale
B
Analog input
S
Serial scale or
iQUBE
2
T
Total scale
P
Program scale
z
Port number (for serial scale or
iQUBE
2
only)
.a
iQUBE
2
system identifier (defaults to .1)
SC.GRADS#n
Graduations
1–9999999
SC.SPLIT#n
Multi-range or multi-interval
scale type
OFF, 2RNG, 3RNG, 2INTVL, 3INTVL
SC.ZTRKBND#n
Zero track band
0, 0–100
Table 9-3. SCALES Serial Commands