Esc "d" [n] k nul – Citizen Systems iDP3420 User Manual
Page 87
iDP3420/3421/3423 User’s Manual
71
CITIZEN
ESC "D" [n] k NUL
[Function]
Setting the horizontal tab position
[Code]
<1B>H <44>H [n] k <00>H
[Range]
1
≤
n
≤
Max. print columns – 1
1
≤
k
≤
16
[Outline]
This command sets the horizontal tab positions.
n indicates the number of lines from the
head of the line to the horizontal tab setting position; n equals the set column position - 1."
k indicates the number of horizontal tab positions to be set.
The tab position is set at the character width
×
n from the head of the line.
The character
width at this time includes the right space of the character and will be doubled if the double
width characters are specified.
The data
<00>H.
ESC D NUL clears all the set tab positions.
After clearing the tab positions, HT
will be ignored.
[Caution]
If the data
horizontal tab setting has been completed.
In that case, the subsequent data will be
processed as regular one.
Up to 16 tab positions can be set.
If the data exceeds this limit, it will be processed as
regular data.
If the data
equal the maximum print columns + 1.
If the character width is changed after setting the horizontal tab positions, they will not
change.