Front plate, Calibrating the touch screen – Kontron OmniClient User Manual
Page 23

OmniClient – User’s Guide (V1.01)
22
www.kontron.com
Operating System and Hardware Component
”). For recalibration of the touch if
necessary, please observe the subsection Error! Reference source not found. “Error! Reference
source not found.”.
Do not use a hard or a pointed object (like screw drivers) to operate the touch
screen, since it can damage the touch screen surface.
The touch screen is covered with a glass panel and care should be taken when
cleaning it (see the section 10.1 “Touch Screen Care and Cleaning”).
7.4.2. Front Plate
The OmniClient system is suitable for installation in an instrument panel or other cabinet. At the
front side of the system, an aluminum front plate (bezel) with integrated anti-glare glass plate
and capacitive touch is located.
For the outline dimensions of the touch monitor base refer to 11.2 “Mechanical Specifications.”
7.4.3. Calibrating the Touch Screen
Unlike resistive touch displays, the capacitive touch screen needs no further calibration after
factory calibration. Only special, conductive styluses (not included) work with capacitive touch
screens.
The capacitive touch screen is factory-calibrated and needs no recalibration.
When using a stylus, make sure to use a special conductive stylus that works with
capacitive touch screens.