BIOS Settings for Fan Control
The fan can be controlled via the BIOS Settings “Advanced Hardware Health”
→
In general 4 modes are possible
» Auto Fan Mode: Temperature Values can be selected to control the Fan
» Fan Always On Full: Fan is always full on
» Fan Disable Mode: Fan is disabled
» Fan Manually Mode: A fixed PWM value (0…255) can be entered to run the fan at a selected speed
The used hardware monitor onboard is an ADT7475. For additional information please refer to the regarding
3.12.1 Electrical Characteristics
Input Voltage Range
8.5V - 18V
Output Voltage
Only 12V (switch in BIOS without function)
Max. output current
0.3A
The Fan out voltage output is not short circuit proof. If necessary the user has to ensure
that the circuit is protected externally, for example by a fuse on the backplane.
To connect a standard FAN with 3pin connector to the module please use adaptor cable
KAB-HSP 200mm (96079-0000-00-0) or KAB-HSP 40mm (96079-0000-00-2)