Com express® module connector connectors j1 and j2, Connector j1 rows a and b pinout – Kontron COMe Eval Carrier QorIQ User Manual

Page 9

background image

www.kontron.com

9

Quick Start Guide

COME-QEC-1

5.2.1 COM Express® Module Connector Connectors J1 and J2

The pinout of the COM-Express® connectors on the COME-QEC-1, the COMe-bP5020 and the COMe-cP2020 boards are specifically
defined for usage with Freescale® QorIQ® CPUs. Steering member for this definition was the CPU manufacturer Freescale®. The
COM-Express® interface is based on two connectors with two rows (Rows A/B and Rows C/D) with 440 pins total (220 pins for
each of the two connectors). The pinouts for these two connectors are as follows

Table 2: Connector J1 Rows A and B Pinout

COMMENT

SIGNAL

PIN

PIN

SIGNAL

COMMENT

GND

A1

B1

GND

GBE0_MDI3-

A2

B2

GBE0_ACT#

GBE0_MDI3+

A3

B3

1588_CLK_OUT

accessible via J9

GBE0_LINK100#

A4

B4

1588_PULSE_OUT1 accessible via J9

GBE0_LINK1000#

A5

B5

1588_PULSE_OUT2 accessible via J9

GBE0_MDI2-

A6

B6

1588_ALARM_OUT1 accessible via J9

GBE0_MDI2+

A7

B7

1588_ALARM_OUT2 accessible via J9

GBE0_LINK#

A8

B8

1588_TRIG_IN1

accessible via J9

GBE0_MDI1-

A9

B9

1588_TRIG_IN2

accessible via J9

GBE0_MDI1+

A10

B10

1588_CLK_IN

accessible via J9

GND

A11

B11

GND

GBE0_MDI0-

A12

B12

PWRBTN#

debounced signal of Power
switch SW2

GBE0_MDI0+

A13

B13

SMB_CK

buffered version of this signal is
routed to Slot1..4 connectors;
these signals must be enabled
by DIP SW3-3

GBE0_CTREF

A14

B14

SMB_DAT

buffered version of this signal is
routed to Slot1..4 connectors;
these signals must be enabled
by DIP SW3-3

connected to carrier logic and
connector J37; pullup 8k2 to
V_3V3_STDBY on carrier

SUS_S3#

A15

B15

SMB_ALERT#

routed to carrier logic (actually
not used)

for use with COMe-bP5020

SATA0_TX+

A16

B16

SATA1_TX+

for use with COMe-bP5020

for use with COMe-bP5020

SATA0_TX-

A17

B17

SATA1_TX-

for use with COMe-bP5020

N/C

A18

B18

N/C

for use with COMe-bP5020

SATA0_RX+

A19

B19

SATA1_RX+

for use with COMe-bP5020

for use with COMe-bP5020

SATA0_RX-

A20

B20

SATA1_RX-

for use with COMe-bP5020

GND

A21

B21

GND

N/C

A22

B22

N/C

N/C

A23

B23

N/C

Reserved

A24

B24

PWR_OK

used to start onboard supply

N/C

A25

B25

N/C

N/C

A26

B26

N/C

accessible via J37

BATLOW#

A27

B27

WDT

accessible via J37

reserved

RFU

A28..
A30

B28..
B30

RFU

reserved

GND

A31

B31

GND

reserved

RFU

A32

B32

RFU

reserved

reserved

RFU

A33

B33

I2C_CK

available on JP3

N/C

A34

B34

I2C_DAT

available on JP2