2 sensor thresholds, Thresholds - standard temperature range, Voltage sensor thresholds – Kontron AM5030 IPMI User Manual
Page 29: Am5030 ipmi firmware user guide
AM5030
IPMI Firmware User Guide
ID: 1042-7364, Rev. 1.0
Page 29
4.2
Sensor Thresholds
The AM5030 CPU module is available with only one operating temperature range. The stan-
dard temperature range threshold is defined by Table 10. Table 11 provides voltage sensor
thresholds.
Table 10: Thresholds - Standard Temperature Range
Sensor Number /
ID string
15h /
A1:Temp
AMC In
16h /
A1:Temp
Air
Upper non-recoverable
85 °C
95 °C
Upper critical
80 °C
90 °C
Upper non critical
70 °C
80 °C
Normal max
65 °C
75 °C
Nominal
55 °C
65 °C
Normal min
0 °C
0 °C
Lower non-critical
-5 °C
-5 °C
Lower critical
-7 °C
-7 °C
Lower non-recoverable
-10 °C
-10 °C
Table 11: Voltage Sensor Thresholds
Sensor Number /
ID string
17h /
A1:Board
3.3vIPM
18h /
A1:Board
12.0v
19h /
A1:Board
5.0V
1Ah /
A1:Board
3.3V
Upper non-recoverable
n.a.
n.a.
n.a.
n.a.
Upper critical
3.50 V
13.4 V
5.36 V
3.50 V
Upper non critical
n.a.
n.a.
n.a.
n.a.
Normal max
3.46 V
13.2 V
5.31 V
3.46 V
Nominal
3.30 V
12.0 V
5.00 V
3.30 V
Normal min
3.13 V
10.8 V
4.70 V
3.13 V
Lower non-critical
n.a.
n.a.
n.a.
n.a.
Lower critical
3.11 V
10.7 V
4.67 V
3.11 V
Lower non-recoverable
n.a.
n.a.
n.a.
n.a.