beautypg.com

Ipmi firmware user guide am5010 – Kontron AM5010 IPMI User Manual

Page 24

background image

IPMI Firmware User Guide

AM5010

Page 24

© 2008 Kontron AG

ID 1022-2948, Rev. 1.0

18
Board 12.0v

Voltage (02h) / Threshold (
01h)

2204h /
2204h /

1212h

AMC Payload Power
(PWR) 12V

Y

19
Board 5.0V

Voltage (02h) / Threshold (
01h)

2204h /
2204h /

1212h

Board 5V supply

Y

20
Board 3.3V

Voltage (02h) / Threshold (
01h)

2204h /
2204h /

1212h

Board 3.3V supply

Y

21
Board 1.8V

Voltage (02h) / Threshold (
01h)

2204h /
2204h /

1212h

Board 1.8V supply

Y

22
Board 1.5V

Voltage (02h) / Threshold (
01h)

2204h /
2204h /
1212h

Board 1.5V supply

Y

23
Board Vtt0.9V

Voltage (02h) / Threshold (
01h)

2204h /
2204h /

1212h

DDR termination
supply

Y

24
Pwr Good

Power supply (08h) / OEM

(77h)

0000h /

0000h /
18B7h

Statuses of all power

lines

N

25
Pwr Good Evt

Power supply (08h) / OEM
(77h)

0000h /
18B7h /

18B7h

Power fail events for
all power lines

Y

26
CPU status

Processor (07h) / Sensor-
specific (6Fh)

0002h /
0002h /

0002h

CPU thermal alarm
sensor

N

27
Board NMI

Critical interrupt (13h) /
Digital discrete (03h)

0002h /
0000h /

0003h

CPU NMI signal

N

28
SMI Timeout

Critical interrupt (13h) /
Digital discrete (03h)

0002h /
0000h /

0003h

Time out during SMI
processing

N

29
FWH0 Boot Err

Boot Error (1Eh) / Sensor-
specific

0008h /
0008h /
0008h

Firmware Hub 0 boot
error

Y

30
FWH1 Boot Err

Boot Error (1Eh) / Sensor-
specific

0008h /
0008h /

0008h

Firmware Hub 1 boot
error

Y

31
POST Value

OEM Post Value (C6h) /
OEM (78h)

0000h /
0000h /
00FFh

POST Value (from
host I/O port 80h)

N

32
Lan Front0 Lk

LAN (27h) / Sensor-
specific

0000h /
0000h /

0003h

LAN Front link status
or LAN port 8 status

(if supported by the

module)

N

33
Lan Front1 Lk

LAN (27h) / Sensor-
specific

0000h /
0000h /

0003h

LAN port 9 status (if
supported by the

module)

N

34

LAN (27h) / Sensor-

0000h /

LAN port 0 status

N