Ipmi firmware user guide am5010 – Kontron AM5010 IPMI User Manual
Page 24
IPMI Firmware User Guide
AM5010
Page 24
© 2008 Kontron AG
ID 1022-2948, Rev. 1.0
18
Board 12.0v
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
AMC Payload Power
(PWR) 12V
Y
19
Board 5.0V
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
Board 5V supply
Y
20
Board 3.3V
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
Board 3.3V supply
Y
21
Board 1.8V
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
Board 1.8V supply
Y
22
Board 1.5V
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
Board 1.5V supply
Y
23
Board Vtt0.9V
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
DDR termination
supply
Y
24
Pwr Good
Power supply (08h) / OEM
(77h)
0000h /
0000h /
18B7h
Statuses of all power
lines
N
25
Pwr Good Evt
Power supply (08h) / OEM
(77h)
0000h /
18B7h /
18B7h
Power fail events for
all power lines
Y
26
CPU status
Processor (07h) / Sensor-
specific (6Fh)
0002h /
0002h /
0002h
CPU thermal alarm
sensor
N
27
Board NMI
Critical interrupt (13h) /
Digital discrete (03h)
0002h /
0000h /
0003h
CPU NMI signal
N
28
SMI Timeout
Critical interrupt (13h) /
Digital discrete (03h)
0002h /
0000h /
0003h
Time out during SMI
processing
N
29
FWH0 Boot Err
Boot Error (1Eh) / Sensor-
specific
0008h /
0008h /
0008h
Firmware Hub 0 boot
error
Y
30
FWH1 Boot Err
Boot Error (1Eh) / Sensor-
specific
0008h /
0008h /
0008h
Firmware Hub 1 boot
error
Y
31
POST Value
OEM Post Value (C6h) /
OEM (78h)
0000h /
0000h /
00FFh
POST Value (from
host I/O port 80h)
N
32
Lan Front0 Lk
LAN (27h) / Sensor-
specific
0000h /
0000h /
0003h
LAN Front link status
or LAN port 8 status
(if supported by the
module)
N
33
Lan Front1 Lk
LAN (27h) / Sensor-
specific
0000h /
0000h /
0003h
LAN port 9 status (if
supported by the
module)
N
34
LAN (27h) / Sensor-
0000h /
LAN port 0 status
N