IPMI Info-2
(C0h) / OEM (71h)
7FFFFh
2
IPMI Watchdog
Watch dog (23h) /
Sensor-specific
010Fh /
0000h /
010Fh
Watchdog 2
Y
3
FRU Agent
OEM (C5h) / Discrete
(0Ah)
0140h /
0000h /
0147h
FRU agent
N
4
Health Error
Platform Alert (24h) /
Digital discrete (03h)
0000h /
0000h /
0003h
Aggregate states
(power, temperatures
etc.). Visualization
by the Health LED.
Y
5
MMC Reboot
Platform Alert (24h) /
Digital discrete (03h)
0002h /
0000h /
0003h
MMC reboot active
state. Is asserted
during boot time.
N
6
Ver change
Version change (2Bh) /
Digital discrete (03h)
0002h /
0000h /
0003h
Version change
N
7
ModuleHotSwap
OEM (F2h) / Sensor-
specific
0007h /
0000h /
0007h
Hot swap sensor
N
8
IPMBL State
OEM (C3h) / Sensor-
specific
000Fh /
0000h /
000Fh
State of IPMB-L bus
N
9
Storage Err
Management subsystem
health (28h) / Sensor-
specific
0002h /
0000h
Storage error
N
10
Board Reset
OEM (C4h) / Sensor-
specific
04DEh /
0000h
Board reset event
Y
11
Temp CPU
Temperature (01h) /
Threshold (01h)
0280h /
3280h /
1818h
CPU die temperature
Y
12
Temp MCH
Temperature (01h) /
Threshold (01h)
0280h /
3280h /
1818h
MCH die temperature
Y
13
Temp CPU In
Temperature (01h) /
Threshold (01h)
0280h /
3280h /
1818h
Inlet (mid-board)
temperature near
CPU
Y
14
Temp AMC Out
Temperature (01h) /
Threshold (01h)
0280h /
3280h /
1818h
Outlet temperature
near AMC connector
Y
15
Temp AMC In
Temperature (01h) /
Threshold (01h)
0280h /
3280h /
1818h
Inlet (mid-board)
temperature near
AMC connector
Y
16
Temp CPU Out
Temperature (01h) /
Threshold (01h)
0280h /
3280h /
1818h
Outlet temperature
near CPU
Y
17
Board 3.3vIPM
Voltage (02h) / Threshold (
01h)
2204h /
2204h /
1212h
AMC Management
Power (MP) 3.3V
Y