beautypg.com

1 xfp ports, Xfp ports - 28, 23 xfp connector pin assignment - 28 – Kontron AT8904 User Manual

Page 61: At8904m hardware description

background image

AT8904M

Hardware Description

Page 3 - 27

AT8904M User Guide

The main building blocks of the AM4310 are:

• XFP Ports

• XAUI to XFI Transceivers

• IPMI

• Power Supply

3.3.1

XFP Ports

The AMC module contains two 10 GbE XFP uplinks at the front panel. XFP modules are not
provided with the AM4310 and have to be obtained separately. The XFP uplink ports are ac-
cording to the SFF Committee, INF-80077i, rev. 4.0, 10 Gigabit Small Form Factor Pluggable
Module (XFP). Modules with -5.0V are not supported. An application note with a list of XFP
modules successfully operated in the AM4310 is available upon request.

The XFP cages have the following pin assignment.

Caution!
Do not look into the laser beam!
The XFP modules are fitted with a class 1 or 1M laser. To avoid possible
exposure to hazardous levels of invisible laser radiation, do not exceed max-
imum ratings.

Warning!

The XFP cages have heatsinks which can dissipate 1.5W with no airflow. If
the XFP module consumes more than 1.5W (up to 3.5W), the user has to
ensure sufficient airflow to cool the XFP module. Otherwise, the modules
may be damaged.

Table 3-23: XFP Connector Pin Assignment

Pin No

Signal

Description

1

GND

Module Ground

2

VEE5

Not connected

3

MOD_DE_SEL

Module De-select; When held low, allows module to
respond to 2-wire serial interface

4

INTERRUPT#

Not connected

5

TX_DIS

Transmitter Disable; Turns off transmitter laser output

6

VCC5

+5V Power Supply

7

GND

Module Ground

8

VCC3

+3.3V Power Supply

9

VCC3

+3.3V Power Supply

10

SCL

I²C Serial Interface Clock

11

SDA

I²C Serial Interface Data Line