R614, R616, or R623 (Dual)

Pyrometer














A. Thermocouple Installation

The R6514 Thermocouple mounts between the spark plug and the engine head. The ring
connection should be installed such that it is in contact with the head directly, and no gasket
should be placed between the ring and head surface. The contact surface should be free or rust,
grease, grime, etc.

B. Leadwire Installation

The R653 Leadwire Assembly is installed by connecting the White lead to the positive
Pyrometer terminal, and the Red lead to the negative (unmarked) terminal. Plug the other end of
the Leadwire Assembly into the Thermocouple. (If it should become necessary to replace any of
the terminal ends, use only crimp type terminals – NEVER solder terminals to these wires!!!)

C. Pyrometer Installation

The R614 Pyrometer installs into a 3” mounting hole. Remove the dampening wire across the
center terminals, mount the Pyrometer through the instrument panel, and use the mounting
bracket to secure it. Connect the Leadwire terminals as noted above in paragraph “B”. Install
the light assembly into the Pyrometer, and connect their wires to the existing instrument lighting
circuit. The Pyrometer has been set to ambient (room) temperature at the factory, and should not
require further adjustment.

Notes

1. If the Pyrometer light is too bright, substitute a 28V lamp (GE #1829).
2. If the Pyrometer is slow or erratic, check the leadwires and thermocouple for continuity, and

also for grease or looseness at the terminals.

3. When properly installed the accuracy of the system will be within 2% at 600

°F under average

operating conditions