FEBCO FPHB-1 Key Operated Wall Hydrants for Irrigation System Winterization User Manual
Series fphb-1 wall hydrants, Sizes, Figure 1
IS-F-FPHB-1
I N S T A L L A T I O N I N S T R U C T I O N S
Series FPHB-1 Wall Hydrants
Sizes:
3
⁄
4
" and 1" (20 and 25mm)
Installation Instructions
1. Drill a 1
7
⁄
8
" diameter hole in the wall and insert the barrel through
the wall.
2. Determine system requirements:
a. If using a vacuum breaker, install the union outlet of the FPHB-1
Hydrant in the vertical up position (see Fig. 1 and Fig. 2)
b. If using a Reduced Pressure Assembly, install the union outlet of the
FPHB-1 Hydrant in the vertical up orientation (see Fig. 1 and Fig. 3).
c. If using a Double Check Assembly in meter box (see Fig. 4 and Fig.
5), install the union outlet in the vertical down position.
3. Secure to the wall, anchoring through the faceplate.
4. Connect the threaded
3
⁄
4
" or 1" inlet to the domestic supply. (see Fig. 1)
5. If the inside connection is to be a sweat (soldered) connection, turn
hydrant key counter-clockwise to the full open position. Wrap hydrant
side connection with a wet rag and/or heat sink before applying heat.
6. Restore water supply, slowly open hydrant and flush thoroughly.
7. Connect union outlet to the backflow preventer.
Note: FPHB-1 does not include Backflow Prevention Assembly. Consult
local codes for proper protection.
Note: The FPHB-1 is designed for maximum flow and should be oper-
ated in the wide open position. The FPHB-1 hydrant should not be used
as a throttling valve.
Figure 1
Size
3
⁄
4
" and 1" (20 and 25mm)
model
Nom.
PiPe
Stem
Distance
Length (in.)
Length (in.)
FPHB-1-8
8.0
9.0
12.3
FPHB-1-10
10.0
11.0
14.3
FPHB-1-12
12.00
13.0
16.3
o-Ring
Plumbing Assembly
Valve Body
Head Body
Union Nut
Key
drain Plug,
Blow down
Seat