Connection of tubing illustrated, Go to the system start-up and operation procedures, Ews, inc. / environmental water systems 4.2-14 – Environmental Water Systems RU Series User Manual

Page 14

background image

EWS, Inc. / Environmental Water Systems

4.2-14

www.EWSWATER.com office: 702-256-8182 (m-f; 8:30-4:30, pst) fax: 702-256-3744 [email protected]

Air Gap

Installation and the

5 connections

Non- Air Gap

Installation and the

4 connections

Air Gap use:

1/4”MPT x 3/8” quick connect

fitting connected to drain saddle

strictly for illustration purposes only: RU300C18 shown

Note: 4-& 5-Stage RO Units and those with UV and pump options may have slightly different connection configurations.

Follow Connection of Tubing Instructions, labeling and/or sample tubing.

Never Pull Tube Out To

Remove

Push Collet In To

Release

To Insert, Press Tubing In

Firmly and Completely

CAUTION:

Always leave the tubing provided to allow lifting the unit for filter replacement and maintenance. Make sure
tubing has gentle curves. Roll and secure as needed. Do not bend or kink tubing. We do not recommend
shortening the tubing, however, If needed, at end, cut tube straight and do not flatten. Avoid any tubing
contact to hot water lines.

WARNING:

NEVER ATTEMPT TO REMOVE TUBING BY JUST PULLING.

Follow simple instructions illustrated above to remove properly.

INSPECT:

Upon installation, inspect the connection and give the tubing a gentle “tug” to insure proper connection
and integrity of the fitting.
Inspect the fitting for any damage from shipping, handling, delivery, and/or installation.
STOP, if collet is damaged in any way; call, fax or e-mail customer service for a replacement fitting.

To Test Integrity of Fitting,

Give a Gentle “Tug” To

Insure Proper Connection

See All

Cautions, Warnings and

Inspections

Connection of Tubing Illustrated

Go to the System Start-Up and Operation Procedures

Non-Air Gap use:

1/4”MPT x 1/4” quick connect

fitting connected to drain saddle

Air Gap Tubing Connections:

1/4” black tubing from unit to

1/4” barb at air gap adaptor

3/8” black tubing from 3/8” barb

at air gap adaptor to

1/4”MPT x 3/8” quick connect fitting

at drain saddle

Non-Air Gap Tubing Connection:

1/4” black tubing from unit to

1/4”MPT x 1/4” quick connect fitting

at drain saddle