1. The deglaze and re-glaze procedure must be performed from a swing stage or man lift from the exterior of the building. Follow the sealant manufacture’s

sealant application instruction for deglazing and re-glazing. When deglazing an opening or openings at a structural silicone glazed unit follow these
instructions:

a. Cut and remove the weather seal, side blocks and setting blocks, from around the lite of glazing.
b. Using tools, such as automotive deglazing tools, cut though the glazing sealant removing glazing, old gasket and sealant from the opening. Some

areas may be accessible from the interior.

c. Cut away the sealant from the substrate, leaving a thin film (approximately 1/32” thick) of sealant on the frame. Do not damage the surface finish of

the substrate. Alternatively, if the remaining sealant exhibits adhesive failure, completely remove all sealant, but take care not to damage the
substrate finish.

d. Remove all remaining gasket pieces or sealant residue from inside the gasket reglets.

Section 15 - Deglaze / Re-glaze Procedures - SSG System

Figure 141

Cut completely

through the sealant

joint and remove the
sealant and gaskets.

Cut out and remove

the weather seals.

Remove setting

and side blocks

from the opening of

lite to be deglazed.

Cut out and remove

the weather seals.

Cut completely

through the sealant

joint and remove the
sealant and gaskets.

Cut out and remove

the weather seals.