Before starting installation of your new enclosure, carefully read all
instructions and lay out parts to become familiar with their identity.
Do not try to cut the mirrors or glass used in this enclosure.
Tempered glass and mirrors will disintegrate if cut.
CLEANING
Cleaning and care of your enclosure is important to its lasting beauty. We suggest using a nonabrasive liquid cleaner. Never use
scouring powder or pads.
SEALING
The use of a caulking compound can assure a water-tight seal when applied along outside edge of the enclosure where metal and bath meet.
If desired, caulk inside of enclosure where jambs meet walls.
Anchors are furnished with every enclosure. However, the use of anchors is not recommended when attaching your enclosure to a fiberglass
unit or wall surrounds with board reinforced mounting areas. Mounting holes in this case should be drilled with a 1/8" drill bit.
Mounting of this unit on tile requires the use of anchors. Special care must be taken not to crack the tile. Before drilling holes in the tile, lightly
chip glazed surface of tile at the desired locations. Drill holes using a 3/16" masonry drill bit. Insert anchors into the holes making certain that
ring on large end of anchor meets the surface of the tile.
USE OF ANCHORS
INSTALLATION INSTRUCTIONS
Measure width of shower opening
at threshold and cut sill (A) to that
measurement. If necessary, file
sharp corners of sill to fit contour of
your unit.
Position sill on center of threshold
with tall edge of sill toward outside
of shower. Tape sill to threshold
with masking tape to hold in place
while positioning jambs.
1
Threshold
Centerline
Masking Tape
Sill
A
File sharp corners of sill
as necessary to fit
contour of your unit
Measure
Due to the manufacturing process, there may be rack marks present at one end of your sill and
header. All sills and headers must be trimmed to fit individual openings. When cutting sill and
header, make certain to trim off end with rack marks.
Place jamb (B) on sill with short legs against
wall. If necessary, file back edge (short legs) of
jamb to fit contour of your unit.
Align jamb vertically using a level and mark wall
through prepunched holes. Remove jamb and
drill where marked using 1/8" drill bit. Repeat for
remaining jamb on opposite side.
Reposition one jamb on wall and secure using